Mammography

Biopsy Needles & Accessories

SAMPLE MASTER Semi-Automatic Biopsy System

Click once for a 20mm throw with SAMPLE MASTER needles. Available with or without coaxial introducer needle.

  • One-handed operation for convenient manipulation of guidance device (ultrasound transducer)

  • 10mm-20mm sample notch

  • Echogenic tip for accurate placement under ultrasound guidance
    Centimetre depth markings assist in needle placement

  • Can be used with echogenic co-axial introducer needles

SAMPLE MASTER Co-axial Biopsy System

Allows multiple sampling from one percutaneous puncture with minimal damage to surrounding tissue.

  • Trocar point tip maintains directional stability

  • Blunt tip cannula helps prevent inadvertent distal drift and may reduce risk of tissue trauma

  • Echogenic markings facilitate precise ultrasound positioning

  • Locking skin stop helps prevent forward migration

  • Matched in length to cutting cannula

HYSTO SYSTEM II Disposable Automatic System

With two programmable firing modes, these lightweight automated systems give you the precise control and quality sampling capability you need when working with calcified or fibrous lesions. They can be easily operated with one hand, making them ideal for procedures requiring ultrasound guidance.

  • Available with or without coaxial introducer needle

  • Large 20mm sample notch

  • Echogenic tip for accurate placement under ultrasound guidance

  • Two fire trigger and one end operation

  • Can be used with echogenic co-axial introducer needles

  • One-handed operation for convenient manipulation of guidance device (ultrasound transducer)

HYSTO SYSTEM II Co-axial Biopsy System

Allows multiple sampling from one percutaneous puncture with minimal damage to surrounding tissue.

  • Trocar point tip maintains directional stability

  • Blunt tip cannula helps prevent inadvertent distal drift and may reduce risk of tissue trauma

  • Echogenic markings facilitate precise ultrasound positioning

  • Locking skin stop helps prevent forward migration

  • Matched in length to cutting cannula

COMPACT Programmable Automatic Soft Tissue Biopsy Device

One-handed design simplifies loading and operation whilst allowing for convenient manipulation of the ultrasound transducer.

  • Programmable: releases the stylet allowing time for tissue to settle in notch (ideal for denser tissue or when there is a desire to verify notch position) and activates the cutting cannula

  • Sample notch of 20 mm or 10 mm (Compact Short) offers maximum procedural versatility

  • Coaxial kit for multiple biopsies (US and CT guided)

COMPACT T Short Notch Automatic Soft Tissue Biopsy Device

One-handed design simplifies loading and operation whilst allowing for convenient manipulation of the ultrasound transducer.

  • Programmable: releases the stylet allowing time for tissue to settle in notch (ideal for denser tissue or when there is a desire to verify notch position) and activates the cutting cannula

  • Sample notch of 10mm for critical procedures

  • Thin-wall cannula for larger core

  • Colour coded for quick gauge size identification

  • Depth markings etched on cannula for precise positioning

  • Loaded status indicator

  • Plastic safety protection to avoid accidental firing

COREX Automatic Soft Tissue Biopsy Device

One-handed design simplifies loading and operation whilst allowing for convenient manipulation of the ultrasound transducer.

  • Equipped with a visual and mechanical safety-system

  • Sample notch of 19 mm or 7 mm (Corex Short) offers maximum procedural versatility

  • Coaxial kit for multiple biopsies (US and CT guided)

CT-CORE Single Action Soft Tissue Biopsy Device

Lightweight and compact to facilitate one-handed operation during procedures, Precise, rapid-firing mechanism for an intact core tissue sample.

  • Specimen notch fully exposed when stylet is advanced for ease of sample removal

  • Puncture depth can be adjusted to between 15-22mm

  • Coaxial outer needle for multiple biopsies (US and CT guided)

  • The 14 gauge version features a Trocar point for ease of insertion into dense tissue

INTRO/INTRO PLUS Standard Coaxial Introducer Needle used for Single Access in Multiple Soft Tissue Biopsies

Echogenic treatment for ultrasound guided procedures.

  • Centimetre marking and optional sliding stopper

  • Coaxial-Intro is one gauge smaller than biopsy needle

  • INTRO (code: VVT) with blunt cannula and trocar tip

  • INTRO PLUS (code: VVTC) with sharp cutting cannula and trocar tip

Fine Needle Aspiration (FNA) Biopsy Needles

Fine needle aspiration for cytological and histological evaluation.

  • Sharpened cannula for a safe and painless insertion and penetration

  • Available with echogenic tip, ensuring accurate ultrasound placement

  • Sliding stop and centimetre division promoting accurate depth placement

  • Centimetre marking and colour coded for identification

  • Choice of Chiba, Wescott, Franseen and Spinal Needles

CYTOCAN Fine Needle Aspiration

  • Chiba Needle for Aspiration Biopsy

  • Puncture cannula developed especially for ultrasonic diagnostics

  • Echogenic needle tip assists precise needle tip positioning

  • Adjustable sliding depth stopper - safe for patient and user

  • Graduated puncture cannula to assist in precise depth placement of the needle

  • Colour coded hub for easy identification of needle gauge size

Contact Us

* Required information

At GTA UK Limited we take your privacy seriously and will only use your personal information to manage your account or your enquiry, process your order, to personalise your use of the website, or to post offers of products and services which may be useful to you. We will not share your information for marketing purposes with companies outside of GTA UK Limited. Please refer to our Privacy Policy in full, which can be downloaded here.