Biopsy Needles & Accessories
SAMPLE MASTER Semi-Automatic Biopsy System
Click once for a 20mm throw with SAMPLE MASTER needles. Available with or without coaxial introducer needle.
One-handed operation for convenient manipulation of guidance device (ultrasound transducer)
10mm-20mm sample notch
Echogenic tip for accurate placement under ultrasound guidance
Centimetre depth markings assist in needle placementCan be used with echogenic co-axial introducer needles
SAMPLE MASTER Co-axial Biopsy System
Allows multiple sampling from one percutaneous puncture with minimal damage to surrounding tissue.
Trocar point tip maintains directional stability
Blunt tip cannula helps prevent inadvertent distal drift and may reduce risk of tissue trauma
Echogenic markings facilitate precise ultrasound positioning
Locking skin stop helps prevent forward migration
Matched in length to cutting cannula
HYSTO SYSTEM II Disposable Automatic System
With two programmable firing modes, these lightweight automated systems give you the precise control and quality sampling capability you need when working with calcified or fibrous lesions. They can be easily operated with one hand, making them ideal for procedures requiring ultrasound guidance.
Available with or without coaxial introducer needle
Large 20mm sample notch
Echogenic tip for accurate placement under ultrasound guidance
Two fire trigger and one end operation
Can be used with echogenic co-axial introducer needles
One-handed operation for convenient manipulation of guidance device (ultrasound transducer)
HYSTO SYSTEM II Co-axial Biopsy System
Allows multiple sampling from one percutaneous puncture with minimal damage to surrounding tissue.
Trocar point tip maintains directional stability
Blunt tip cannula helps prevent inadvertent distal drift and may reduce risk of tissue trauma
Echogenic markings facilitate precise ultrasound positioning
Locking skin stop helps prevent forward migration
Matched in length to cutting cannula
COMPACT Programmable Automatic Soft Tissue Biopsy Device
One-handed design simplifies loading and operation whilst allowing for convenient manipulation of the ultrasound transducer.
Programmable: releases the stylet allowing time for tissue to settle in notch (ideal for denser tissue or when there is a desire to verify notch position) and activates the cutting cannula
Sample notch of 20 mm or 10 mm (Compact Short) offers maximum procedural versatility
Coaxial kit for multiple biopsies (US and CT guided)
COMPACT T Short Notch Automatic Soft Tissue Biopsy Device
One-handed design simplifies loading and operation whilst allowing for convenient manipulation of the ultrasound transducer.
Programmable: releases the stylet allowing time for tissue to settle in notch (ideal for denser tissue or when there is a desire to verify notch position) and activates the cutting cannula
Sample notch of 10mm for critical procedures
Thin-wall cannula for larger core
Colour coded for quick gauge size identification
Depth markings etched on cannula for precise positioning
Loaded status indicator
Plastic safety protection to avoid accidental firing
COREX Automatic Soft Tissue Biopsy Device
One-handed design simplifies loading and operation whilst allowing for convenient manipulation of the ultrasound transducer.
Equipped with a visual and mechanical safety-system
Sample notch of 19 mm or 7 mm (Corex Short) offers maximum procedural versatility
Coaxial kit for multiple biopsies (US and CT guided)
CT-CORE Single Action Soft Tissue Biopsy Device
Lightweight and compact to facilitate one-handed operation during procedures, Precise, rapid-firing mechanism for an intact core tissue sample.
Specimen notch fully exposed when stylet is advanced for ease of sample removal
Puncture depth can be adjusted to between 15-22mm
Coaxial outer needle for multiple biopsies (US and CT guided)
The 14 gauge version features a Trocar point for ease of insertion into dense tissue
INTRO/INTRO PLUS Standard Coaxial Introducer Needle used for Single Access in Multiple Soft Tissue Biopsies
Echogenic treatment for ultrasound guided procedures.
Centimetre marking and optional sliding stopper
Coaxial-Intro is one gauge smaller than biopsy needle
INTRO (code: VVT) with blunt cannula and trocar tip
INTRO PLUS (code: VVTC) with sharp cutting cannula and trocar tip
Fine Needle Aspiration (FNA) Biopsy Needles
Fine needle aspiration for cytological and histological evaluation.
Sharpened cannula for a safe and painless insertion and penetration
Available with echogenic tip, ensuring accurate ultrasound placement
Sliding stop and centimetre division promoting accurate depth placement
Centimetre marking and colour coded for identification
Choice of Chiba, Wescott, Franseen and Spinal Needles
CYTOCAN Fine Needle Aspiration
Chiba Needle for Aspiration Biopsy
Puncture cannula developed especially for ultrasonic diagnostics
Echogenic needle tip assists precise needle tip positioning
Adjustable sliding depth stopper - safe for patient and user
Graduated puncture cannula to assist in precise depth placement of the needle
Colour coded hub for easy identification of needle gauge size